Tile Roof Wind Load Certification — Hialeah Gardens, FL
Replacing Your Roof in Hialeah Gardens? Florida’s strict building codes require that all roofing projects meet specific wind load standards, especially within the High-Velocity Hurricane Zone (HVHZ). If you’re installing a new tile roof, your project isn’t complete until you have a site-specific, engineer-certified wind load letter.
Oasis Engineering
7/4/20251 min read
Replacing Your Roof in Hialeah Gardens?
Florida’s strict building codes require that all roofing projects meet specific wind load standards, especially within the High-Velocity Hurricane Zone (HVHZ). If you’re installing a new tile roof, your project isn’t complete until you have a site-specific, engineer-certified wind load letter.
Oasis Engineering provides fast, reliable wind calculations and sealed engineering letters to ensure your tile roof complies with:
✅ Florida Building Code (FBC) 2023 — 8th Edition
✅ ASCE 7-22 Wind Load Requirements
✅ Miami-Dade HVHZ Standards
🏠 Project Example: Tile Roof Certification — Hialeah Gardens
For this Hialeah Gardens property, the homeowner needed engineering documentation to approve a concrete tile roofing system. The project included:
Installation of Estate S Tile, a high-quality concrete tile suitable for hurricane zones.
Polyglass TU Plus Underlayment, a self-adhered underlayment system meeting NOA requirements.
Compliance with RAS 127 installation standards for roof tile systems.
📏 Our Engineering Process
Oasis Engineering provided:
✅ Site-Specific Wind Calculations
We determined precise wind pressures based on property location, roof slope, and height:
Risk Category II
Design Wind Speed: 175 mph (HVHZ requirement)
Exposure Category: C
Mean Roof Height: ~12.5 ft
Required Pressures by Zone:
➤ Zone 1: –64 psf
➤ Zone 2: –85 psf
➤ Zone 3: –110 psf
✅ Product NOA Verification
All materials were confirmed compliant:
Estate S Tile: FL NOA 22-0201.09
Polyglass TU Plus Underlayment: FL NOA 22-1221.01
✅ Sealed Engineering Letter & Permit Package
We issued:
PE-signed wind load certification
Full calculations package
Product Approval documentation
Completed HVHZ Uniform Roofing Application
The client received a complete, permit-ready package, accepted by city officials to move the project forward.
🎯 Why Tile Roof Wind Certifications Matter
Uncertified roofing systems risk:
🚫 Permit rejections
🚫 Failed inspections
🚫 Compromised hurricane protection
Florida’s strict enforcement protects homes from high-wind damage, but navigating the codes requires expertise. Oasis Engineering simplifies the process with fast, expert-certified solutions.
⚡ Order Your Tile Roof Certification Today
Visit WindCalculations.com to:
✔ Order site-specific wind load letters for tile roofs
✔ Access PE-certified documentation in as little as 2 business days
✔ Ensure full code compliance with FBC, ASCE 7-22, and NOA standards
Trust Oasis Engineering for reliable, fast, and compliant wind certifications — proudly serving Hialeah Gardens and all HVHZ communities.
WindCalculations.com
+1 (813) 694-8989
info@windcalculations.com
© 2023 Oasis Engineering LLC. All rights reserved. Doing business as WindCalculations.com