Skip to content
Learn · WindCalculations

Designed for Solar, But Is It Ready for Solar? A Boulder County Structural Engineering Case Study

See how our engineers evaluated a relocated 10.6 kW solar array on a Colorado pole barn, resolving wind, snow and attachment issues without structural reinforcement.

Oasis EngineeringNovember 27, 20269 min read

Illustration of a post-frame barn with rooftop solar panels and the Boulder Flatirons behind it (not the project building)

Illustration above: a post-frame barn with rooftop solar in the Boulder foothills. It is not the project building.

A building can be specifically designed to support solar panels and still have a proposed solar installation that exceeds the capacity of its structural components.

That is exactly what we encountered during a recent structural engineering evaluation of a roof-mounted solar array on a post-frame agricultural building in Boulder County, Colorado.

The building was designed to accommodate an additional 10 pounds per square foot (psf) of solar loading. The proposed solar array weighed approximately 2.9 psf — less than one-third of that allowance.

Yet the original attachment configuration did not satisfy several structural requirements.

By evaluating the actual load path and optimizing the solar panel attachment layout, we identified a configuration that satisfied the preliminary structural calculations without requiring additional structural reinforcement.

Project Overview

The property owner wanted to relocate an existing ground-mounted solar array onto the roof of a newly constructed post-frame agricultural building.

The project included:

  • Location: Unincorporated Boulder County, Colorado
  • Building type: Post-frame agricultural building
  • Main roof dimensions: 40 × 60 feet
  • Roof slope: 3:12
  • Roof covering: 26-gauge ribbed metal roofing
  • Structural framing: Wood trusses spaced 12 feet on center
  • Roof purlins: 2×8 Douglas Fir No. 2, spaced 24 inches on center
  • Solar system capacity: 10.6 kW DC
  • Solar modules: 40 Q CELLS 265-watt modules
  • Mounting rails: Reused S:FLEX aluminum rails
  • Roof attachments: S-5! VersaBracket-47
  • Existing structural solar allowance: 10 psf

The owner contacted us through our online Boulder roof-mounted solar wind certification service to obtain the engineering documentation needed for the County solar permitting process.

Why a Roof Designed for Solar May Still Require Structural Engineering

One of the most common misconceptions about rooftop solar installations is that an existing solar load allowance automatically establishes the suitability of any solar mounting configuration.

A structural solar allowance generally accounts for additional distributed weight on the roof. However, solar panels transfer their loads through individual clamps, rails, mounting brackets, fasteners and structural framing members.

The complete load path must be evaluated:

Solar panels → Module clamps → Mounting rails → Roof brackets → Fasteners → Purlins → Trusses → Supporting structure

Each component must have sufficient capacity to resist the forces transferred through it.

In this project, the total weight of the solar panels was well below the building's original solar allowance. The primary concerns were concentrated attachment loads, wind uplift, snow accumulation and the positioning of the array relative to the roof's structural framing.

Engineering Design Criteria

Our preliminary structural evaluation used the design criteria documented in the building's existing approved structural drawings.

Design Parameter Value
Building Code 2021 International Building Code
Loading Standard ASCE 7-16
Wood Design Standard 2018 NDS
Ultimate Design Wind Speed 135 mph
Wind Exposure Category C
Risk Category I
Ground Snow Load 40 psf
Balanced Roof Snow Load Approximately 27 psf
Additional Unbalanced Snow Load Near Ridge Approximately 16 psf
Solar Array Dead Load Approximately 2.9 psf

These criteria were specific to this building and its documented design basis. Wind speed, exposure, risk category, snow loading and applicable code editions must be established individually for each project.

Final engineering documentation remains subject to confirmation of the applicable design criteria and completion of the final wind-loading review.

What We Found in the Original Solar Panel Layout

1. Concentrated Loads on Wood Roof Purlins

The original mounting arrangement included 99 brackets, generally spaced approximately four feet apart along most of the mounting rails.

However, the roof purlins were spaced two feet on center.

This meant that most of the rails transferred their loads to alternating purlins rather than distributing them across every available framing member.

Although the total solar array weight was relatively small, the concentrated bracket reactions significantly increased the demand on individual purlins.

The existing purlins were also already approaching their calculated capacity under certain unbalanced snow-loading conditions.

Adding more weight was not necessarily the primary problem. How that weight and other environmental loads were transferred into the structure was critical.

2. Increased Wind Uplift Near the Roof Ridge

The original solar array layout positioned the upper edge of the modules approximately 24 inches from the roof ridge.

Under the applicable wind-loading methodology, portions of the roof near ridges and edges can experience increased wind pressures.

Solar modules located at exposed edges of an array can also experience additional aerodynamic loading.

Our analysis evaluated wind pressures based on the location of individual modules, rather than applying a single uniform pressure to the entire solar array.

This allowed us to identify opportunities to reduce the calculated wind uplift by adjusting the array's position.

3. Reusing Ground-Mounted Solar Rails

The owner intended to reuse the aluminum mounting rails from the existing ground-mounted solar system.

Although this approach offered potential material savings, the previous installation did not establish the rails' suitability for a rooftop application.

We evaluated the rail bending demands, support spacing and concentrated loads from the module clamps.

The preliminary analysis indicated that rail bending was not a governing concern, with a calculated demand-to-capacity ratio of approximately 0.30 under the evaluated conditions.

This allowed the existing rails to remain part of the proposed configuration, subject to the documented assumptions and final engineering review.

4. Solar Module Clamp Locations

The structural capacity of a solar module can depend on where its mounting clamps are installed.

Small adjustments to the rail positions were necessary to accommodate the ribs of the metal roof and avoid conflicts with the underlying trusses.

We accounted for these adjustments by evaluating the applicable lower module load rating associated with the resulting clamp locations.

This is an important detail when relocating existing solar equipment or using mounting configurations that differ from the original installation.

The Engineering Solution: Optimize the Layout Instead of Reinforcing the Roof

Rather than immediately recommending additional framing, we evaluated alternative attachment configurations.

Three primary changes resolved the identified deficiencies in the preliminary calculations.

Component Original Layout Revised Layout
Roof mounting brackets 99 144
Bracket spacing Approximately 4 feet on most rails Every roof purlin
Upper array setback from ridge 24 inches 50 inches
West array setback 42–48 inches Approximately 56 inches

Install a Bracket at Every Purlin

Increasing the number of mounting brackets from 99 to 144 distributed the solar array reactions across all available purlins beneath each rail.

This reduced the concentrated demand on individual framing members and improved the distribution of wind and gravity loads.

Move the Solar Array Away From the Ridge

Increasing the upper setback from 24 inches to 50 inches positioned the upper row of modules outside the calculated higher-pressure ridge strip used in the preliminary analysis.

This reduced the calculated wind uplift demand associated with that portion of the array.

Coordinate the Rails With the Existing Roof Framing

Adjusting the west edge of the array to approximately 56 inches from the roof edge allowed the mounting rails to avoid conflicts with the truss locations.

Limited rail adjustments were also incorporated to accommodate the metal roofing ribs and maintain the evaluated module clamp configuration.

Project Results

The revised mounting configuration satisfied the preliminary structural checks under the evaluated design criteria without requiring:

  • Additional roof purlins
  • Sistering of existing wood framing
  • Truss reinforcement
  • Replacement of the existing solar mounting rails
  • Major modifications to the building structure

The owner accepted the revised solar mounting layout.

The project demonstrates how structural engineering can identify practical installation improvements rather than immediately recommending expensive structural modifications.

As of November 27, 2026, the structural letter remains preliminary, pending County confirmation of the applicable design criteria and completion of the final wind coefficient review.

A More Efficient Approach to Solar Structural Engineering

For this project, we performed an initial structural analysis using clearly documented preliminary assumptions and the available building drawings.

Instead of sending multiple individual information requests, we provided the owner with preliminary engineering findings and a consolidated list of nine items to confirm or correct.

The owner responded the same day with the requested information, including:

  • Roof framing dimensions and spacing
  • Photographs of wood grade stamps
  • Photographs of existing framing connections
  • Solar module identification labels
  • Mounting system information
  • Original truss drawings

We incorporated the confirmed information into our structural calculations and developed the revised mounting layout.

Within approximately three days, the owner had an evaluated revised configuration, and the supporting engineering documentation had been developed for final review.

The project documentation included:

  • Preliminary engineering findings and information request
  • Structural engineering letter
  • Supporting structural calculations
  • Appendix of relevant building drawings, mounting details and manufacturer documentation

Our objective is to make engineering efficient, accessible and practical while maintaining the technical requirements necessary for responsible structural evaluation.

Frequently Asked Questions

Can I move my ground-mounted solar panels onto a barn or shop roof?

Potentially, yes. However, the existing roof structure, solar modules, mounting rails, brackets and fasteners must be suitable for the proposed rooftop installation.

A ground-mounted system should not automatically be assumed suitable for rooftop use, where wind pressures, snow loading and structural support conditions can differ substantially.

My building was designed for solar panels. Do I still need a structural engineering letter?

Depending on the permitting requirements and installation configuration, you may still need a project-specific structural engineering evaluation.

An existing solar load allowance does not necessarily establish the capacity of individual mounting brackets, fasteners, rails or concentrated loads on roof framing members.

How many mounting brackets does a rooftop solar array need?

There is no universal bracket spacing that applies to every solar installation.

The required number and spacing depend on wind loads, snow loads, mounting system capacity, rail spans, structural framing, fastener capacities and the location of the array on the roof.

Can S-5! VersaBrackets be installed on a ribbed metal roof over wood purlins?

Such a configuration can be evaluated for structural suitability using the applicable manufacturer requirements, attachment capacities, fastener specifications and supporting framing conditions.

The suitability of the bracket alone does not establish the capacity of the complete structural load path.

What wind speed applies to rooftop solar panels in Boulder County?

The applicable design wind speed depends on the project location, risk category, adopted building code and site conditions. Our free Boulder County wind speed tool shows the local design wind speed for an address.

For this particular project, the preliminary evaluation used a 135 mph ultimate design wind speed and Exposure Category C, consistent with the existing building's documented structural design criteria.

These values should not be assumed to apply to every property in Boulder County.

Can solar panels be installed on a pole barn without reinforcing the roof?

In some cases, yes.

Optimizing bracket spacing, distributing loads across additional framing members and adjusting the array's location can reduce structural demands without requiring reinforcement.

A project-specific structural evaluation is necessary to determine whether this approach is appropriate.

Need a Solar Structural Engineering Letter in Boulder County?

Whether you are installing a new rooftop solar system, relocating an existing ground-mounted array or installing solar panels on a metal building, barn, workshop or agricultural structure, our engineering team can help evaluate your proposed installation.

Our solar structural engineering services can include:

  • Review of existing structural drawings
  • Roof-mounted solar wind and snow load calculations
  • Solar mounting bracket and fastener evaluations
  • Roof framing and purlin capacity checks
  • Mounting layout recommendations
  • Project-specific structural engineering letters
  • Supporting calculations for building permit submissions

Request your Boulder County roof-mounted solar structural certification through WindCalculations.com. For a barn, shop or other agricultural or commercial building, choose Commercial as the building type and we will send you a quote.

Our goal is to identify practical, structurally sound solutions that make the best use of your existing building and equipment.

This case study describes a project-specific preliminary engineering evaluation. The design criteria, attachment spacing and mounting configuration discussed are not standard installation details and should not be applied to other structures without an appropriate engineering review. Manufacturer names are provided for technical identification only and do not imply manufacturer endorsement. Final certification and permitting remain subject to applicable requirements and final engineering review.

Need this calculated for your permit?

Set-price packages for doors, windows, roofing, solar and poles, or a same-day proposal for anything else. A licensed engineer reads every request.

Request wind calculations